{"product_id":"4000-litres-per-hour-industrial-reverse-osmosis-system","title":"4000 LPH RO System","description":"\u003ch2\u003ePLEASE NOTE!\u003c\/h2\u003e\n\u003cp\u003eWhen you consider purchasing this system, you need to know the following information as it is very important. This system requires a pretreatment setup for it to perform like it was designed to.\u003ca data-elementor-lightbox-title=\"typical ro system setup-159\" data-elementor-open-lightbox=\"yes\" href=\"https:\/\/www.puritech.co.za\/wp-content\/uploads\/2021\/01\/typical-ro-system-setup-159-scaled.jpg\"\u003e\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe pretreatment setup is not guaranteed to work unless recommended by a sales agent according to the \u003cstrong\u003ewater analysis report\u003c\/strong\u003e from a lab.\u003c\/p\u003e\n\u003cp\u003eA \u003cstrong\u003ewater analysis report\u003c\/strong\u003e is very important as it determines the pretreatment setup needed to be installed before the reverse osmosis system. As you can see on the sketch above, the pretreatment consists of a Sand\/Glass Filter, Carbon Filter, and Antiscalant Dosing system.\u003c\/p\u003e\n\u003cp\u003ePretreatment setups can consist of even more items installed before the reverse osmosis system. Below is a list of items that could be required as per the water analysis report.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e⁠Sand\/ Glass Filtration\u003c\/li\u003e\n\u003cli\u003eCarbon Filtration\u003c\/li\u003e\n\u003cli\u003e⁠⁠DMI Iron Removal Filter Media\u003c\/li\u003e\n\u003cli\u003eSoftener Hardness Removal System\u003c\/li\u003e\n\u003cli\u003e⁠⁠Anti-Scale Dosing System\u003c\/li\u003e\n\u003cli\u003e⁠⁠Chlorine Dosing System\u003c\/li\u003e\n\u003cli\u003eUltrafiltration System\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eOnce all the equipment has been purchased, you will need a qualified technician to put together the complete setup. We have our own qualified technicians train by the manufacturers of the equipment to do the installation running of the setup. Should you require us to install the system for you, a quote with the installation fee will be sent to you by the sales agent in charge.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eIndustrial Reverse osmosis pure water filtration systems technology is the most advanced and energy-saving membrane separation technology. The main working principle is to remove dissolved salt, colloid, microbial organisms under the action of osmosis pressure. As the RO membrane aperture is very small (only 10A), so other material cannot pass through a semi-permeable membrane. \u003cbr\u003eThe solute is retained on the pressurized side of the membrane and the pure solvent is allowed to pass to the RO membrane. This membrane should not allow large molecules or ions through the pores but should allow smaller components of the solution (such as solvent molecules) to pass the \u003ca href=\"https:\/\/www.puritech.co.za\/product-category\/membrane-elements\/\"\u003eRO membrane\u003c\/a\u003e. \u003cbr\u003eThe pumps used in industrial reverse osmosis water filtration systems include Shimge and CNP \u003ca href=\"https:\/\/www.puritech.co.za\/product-category\/pump\/\"\u003epumps\u003c\/a\u003e that have passed ISO9001 quality system certification, ISO14001 environmental management system certification, CE certification, and material is stainless steel so as to prevent rust and pressure. This product is widely used in the food industry, such as juice, milk tea, infusion and cleaning for hospitals, etc. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003eProduct Advantages\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eRO membrane‘s aperture is very small\u003c\/li\u003e\n\u003cli\u003eEasy installation\u003c\/li\u003e\n\u003cli\u003eThe most advanced and energy-saving membrane separation technology\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch3\u003eFunction\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ctable style=\"width: 70.7204%; height: 258px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" valign=\"top\"\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"404\" valign=\"top\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" valign=\"top\"\u003eprecision filter\u003c\/td\u003e\n\u003ctd width=\"404\" valign=\"top\"\u003eprevent large particles, bacteria, viruses into RO membrane, accuracy is 5um\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" valign=\"top\"\u003eHigh-pressure pump\u003c\/td\u003e\n\u003ctd width=\"404\" valign=\"top\"\u003eProvide the high pressure to RO membrane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" valign=\"top\"\u003eRO system\u003c\/td\u003e\n\u003ctd width=\"404\" valign=\"top\"\u003ethe main part of the plant. The RO membrane's desalting rate can reach 99%, removing over 99% of ions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" valign=\"top\"\u003eUV sterilizer\u003c\/td\u003e\n\u003ctd width=\"404\" valign=\"top\"\u003ekill bacteria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003ctable style=\"width: 49.4194%; height: 504px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"240\" valign=\"center\"\u003eCapacity\u003c\/td\u003e\n\u003ctd width=\"175\" valign=\"center\"\u003e4000LPH\/24000GPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"240\" valign=\"center\"\u003eVoltage\u003c\/td\u003e\n\u003ctd width=\"175\" valign=\"center\"\u003e220V\/50Hz,220V\/60Hz, Single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"240\" valign=\"center\"\u003eRecovery\u003c\/td\u003e\n\u003ctd width=\"175\" valign=\"center\"\u003e50%-70%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"240\" valign=\"center\"\u003eDesalination\u003c\/td\u003e\n\u003ctd width=\"175\" valign=\"center\"\u003e96%-99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"240\" valign=\"center\"\u003eMembrane Qty\u003c\/td\u003e\n\u003ctd width=\"175\" valign=\"center\"\u003e2pcs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"240\" valign=\"center\"\u003eTemp of raw water\u003c\/td\u003e\n\u003ctd width=\"175\" valign=\"center\"\u003e1-45℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"240\" valign=\"center\"\u003eFeed Water Pressure\u003c\/td\u003e\n\u003ctd width=\"175\" valign=\"center\"\u003e1-5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"240\" valign=\"center\"\u003eRaw water TDS\u003c\/td\u003e\n\u003ctd width=\"175\" valign=\"top\"\u003e0-1000ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"240\" valign=\"center\"\u003eApplication raw water\u003c\/td\u003e\n\u003ctd width=\"175\" valign=\"center\"\u003eTap water, Brackish water, Seawater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"240\" valign=\"center\"\u003eRO Membrane\u003c\/td\u003e\n\u003ctd width=\"175\" valign=\"center\"\u003eVontron, Dow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 55.8855%; height: 865px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"208\" valign=\"top\"\u003e\u003cstrong\u003eItem name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"265\" valign=\"top\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"208\" valign=\"top\"\u003ePressure gauge\u003c\/td\u003e\n\u003ctd width=\"265\" valign=\"top\"\u003eassembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"208\" valign=\"top\"\u003eHP PUMP\u003c\/td\u003e\n\u003ctd width=\"265\" valign=\"top\"\u003eSS304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"208\" valign=\"top\"\u003eRO Membrane housing\u003c\/td\u003e\n\u003ctd width=\"265\" valign=\"top\"\u003eFRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"208\" valign=\"top\"\u003ePure Flowmeter\u003c\/td\u003e\n\u003ctd width=\"265\" valign=\"top\"\u003ePlexiglas Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"208\" valign=\"top\"\u003ewaste Flowmeter\u003c\/td\u003e\n\u003ctd width=\"265\" valign=\"top\"\u003ePlexiglas Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"208\" valign=\"top\"\u003eConductivity meter\u003c\/td\u003e\n\u003ctd width=\"265\" valign=\"top\"\u003eengineering plastics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"208\" valign=\"top\"\u003ePressure switch\u003c\/td\u003e\n\u003ctd width=\"265\" valign=\"top\"\u003ebrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"208\" valign=\"top\"\u003e inlet valve\u003c\/td\u003e\n\u003ctd width=\"265\" valign=\"top\"\u003ebrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"208\" valign=\"top\"\u003eflush valve\u003c\/td\u003e\n\u003ctd width=\"265\" valign=\"top\"\u003ebrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"208\" valign=\"top\"\u003eRegulating valve\u003c\/td\u003e\n\u003ctd width=\"265\" valign=\"top\"\u003ebrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"208\" valign=\"top\"\u003eUV sterilizer\u003c\/td\u003e\n\u003ctd width=\"265\" valign=\"top\"\u003eSS304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"208\" valign=\"top\"\u003eElectronic control system\u003c\/td\u003e\n\u003ctd width=\"265\" valign=\"top\"\u003eair switch.electric relay.alternating current contractor.switch.LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"208\" valign=\"top\"\u003econtrol box\u003c\/td\u003e\n\u003ctd width=\"265\" valign=\"top\"\u003eSS304 \/Mild Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"208\" valign=\"top\"\u003eFrame\u003c\/td\u003e\n\u003ctd width=\"265\" valign=\"top\"\u003eSUS304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"208\" valign=\"top\"\u003epipeline\u003c\/td\u003e\n\u003ctd width=\"265\" valign=\"top\"\u003eUPVC 3\/4''\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Pure Drop Technicals","offers":[{"title":"Default Title","offer_id":52213833990449,"sku":"RO4000LPH","price":227700.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0967\/5689\/1953\/files\/4000-LPH-RO-System-28757487681748.jpg?v=1765987598","url":"https:\/\/plantsprozim.com\/products\/4000-litres-per-hour-industrial-reverse-osmosis-system","provider":"Plants Pro","version":"1.0","type":"link"}