{"product_id":"500-litres-per-hour-industrial-ro-system-in-a-cabinet","title":"4000GPD RO System (Chinese)","description":"\u003ch2 style=\"text-align: left;\"\u003ePLEASE NOTE!\u003c\/h2\u003e\n\u003cp style=\"text-align: left;\"\u003eWhen you consider purchasing this system, you need to know the following information as it is very important. This system requires a pretreatment set up for it to perform like it was designed to. The pretreatment setup is not guaranteed to work unless recommended by a sales agent according to the \u003ca href=\"https:\/\/puritech.co.za\/2023\/07\/03\/water-quality-monitoring-and-assessment-techniques\/\"\u003e\u003cstrong\u003ewater analysis report\u003c\/strong\u003e\u003c\/a\u003e from a lab.\u003c\/p\u003e\n\u003cp\u003eA \u003cstrong\u003ewater analysis report\u003c\/strong\u003e is very important as it determines the pretreatment setup needed to be installed before the reverse osmosis system. As you can see on the sketch above, the pretreatment consists of a Sand\/Glass Filter, Carbon Filter, and Antiscalant Dosing system.\u003c\/p\u003e\n\u003cp\u003ePretreatment setups can consist of even more items installed before the reverse osmosis system. Below is a list of items that could be required as per the water analysis report.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e⁠Sand\/ Glass Filtration\u003c\/li\u003e\n\u003cli\u003e⁠Carbon Filtration\u003c\/li\u003e\n\u003cli\u003e⁠⁠DMI Iron Removal Filter Media\u003c\/li\u003e\n\u003cli\u003e⁠⁠Softener Hardness Removal System\u003c\/li\u003e\n\u003cli\u003e⁠⁠Anti-Scale Dosing System\u003c\/li\u003e\n\u003cli\u003e⁠⁠Chlorine Dosing System\u003c\/li\u003e\n\u003cli\u003e⁠Ultrafiltration System\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eOnce all the equipment has been purchased, you will need a qualified technician to put together the complete setup. We have our own qualified technicians train by the manufacturers of the equipment to do the installation running of the setup. Should you require us to install the system for you, a quote with the installation fee will be sent to you by the sales agent in charge.\u003c\/p\u003e\n\u003cp\u003eTraining can also be offered to the guys you want to be the ones installing your setup instead of our technicians.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e500 Litres Per Hour Industrial RO System In A Cabinet\u003c\/h2\u003e\n\u003cp\u003eBlack Cabinet Series \u003ca href=\"https:\/\/www.puritech.co.za\/product-category\/ro-industrial\/\"\u003eIndustrial RO Systems\u003c\/a\u003e are designed to produce low dissolved solids product water from the tap or well water. These systems use a high efficiency, low energy membranes, and run at high recovery offering low maintenance and operational costs. They incorporate carbon filters for chlorine removal, and sediment pre-filtration prior to the RO for a packaged unit that is ready to run out of the box.\u003c\/p\u003e\n\u003ch3\u003eBenefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOver 10 years of experience is reflected in our quality.\u003c\/li\u003e\n\u003cli\u003eCompact, Heavy Duty, Powder Coated Frame.\u003c\/li\u003e\n\u003cli\u003eProven components used throughout the system.\u003c\/li\u003e\n\u003cli\u003eConservatively engineered for reliable long term performance.\u003c\/li\u003e\n\u003cli\u003eFactory tested to ensure trouble-free operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eWhy Puritech Company?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eOver 10,000 commercial\/industrial systems in operation.\u003c\/li\u003e\n\u003cli\u003eFrom packaged systems to custom-engineered Industrial Reverse Osmosis systems, we can take care of your needs.\u003c\/li\u003e\n\u003cli\u003eWe are one of the few companies that have the expertise to provide Reverse Osmosis systems for drinking water, boiler feed-water, seawater, desalination, ultrapure water, USP water, and water reuse.\u003c\/li\u003e\n\u003cli\u003eWe stock more components for all sizes of Industrial RO system than any other company.\u003c\/li\u003e\n\u003cli\u003eWe have earned an enviable reputation for our product quality, performance reliability, and business integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFeatures Of The Industrial RO System\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThin Film Composite Membranes in SS Vessels\u003c\/li\u003e\n\u003cli\u003eBlue Carbon block and 5M\/1M Sediment Prefilters in \u003ca href=\"https:\/\/www.puritech.co.za\/product-category\/filter-housings\/\"\u003eHousings\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eAutomatic Inlet Feed Solenoid Valve\u003c\/li\u003e\n\u003cli\u003eSystem \u0026amp; Recycle Control Valves\u003c\/li\u003e\n\u003cli\u003eLow-Pressure Pump Protection\u003c\/li\u003e\n\u003cli\u003eHigh-Pressure RO Pump\u003c\/li\u003e\n\u003cli\u003e(4) Pressure Gauges: System Pressure, Concentrate Pressure, Filter In, and Filter Out.\u003c\/li\u003e\n\u003cli\u003e(3) Panel Mounted Flow Meters: Permeate, Concentrate, and Recycle Flow.\u003c\/li\u003e\n\u003cli\u003ePowder Coated Carbon Steel Frame\u003c\/li\u003e\n\u003cli\u003eBoxed and Palletised for Shipment\u003c\/li\u003e\n\u003cli\u003eAutomatic Microprocessor Controller\u003c\/li\u003e\n\u003cli\u003eMonitors and\/or Controls\u003c\/li\u003e\n\u003cli\u003eInlet Valve\u003c\/li\u003e\n\u003cli\u003eLow-Pressure Switch\u003c\/li\u003e\n\u003cli\u003eFeed Water Flush at System Shut-Down\u003c\/li\u003e\n\u003cli\u003ePre-Treatment Backwash\/Lockout\u003c\/li\u003e\n\u003cli\u003eSystem On\/Off According to Tank Level\u003c\/li\u003e\n\u003cli\u003e(Floats Purchased Separately)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDetails\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e4,000 GPD Industrial RO System\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e20” Big Blue Carbon Block Filters (3 pcs) 5\/1 Micron Sediment Filter, GAC Filter\u003c\/li\u003e\n\u003cli\u003e4040 Length Thin Film Reverse Osmosis Membranes in SS Housings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Codes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e116= 110v, 1ph, 60hz\u003c\/li\u003e\n\u003cli\u003e216= 220\/230v, 1ph, 60hz\u003c\/li\u003e\n\u003cli\u003e215 = 220\/230v, 1ph, 50hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Pre-Treatment Equipment:\u003c\/h3\u003e\n\u003cp\u003eAll pretreatment equipment and SDI test kits are available from Applied Membranes.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWater Softener: Hardness must be removed if present in feed water prior to the RO system to avoid scaling the membranes.\u003c\/li\u003e\n\u003cli\u003eMultimedia filter: If feed water exceeds \u0026lt;1 NTU turbidity or silt density index (SDI) of 3, media filter pretreatment recommended.\u003c\/li\u003e\n\u003cli\u003eSystems rated at 77°F (25°C) using 1000 ppm sodium chloride solution operating at approx. 200 psi.\u003c\/li\u003e\n\u003cli\u003eCapacity Basis: 24 hrs\/day\u003c\/li\u003e\n\u003cli\u003eMinimum feed pressure to RO System: 40-60 PSI.\u003c\/li\u003e\n\u003cli\u003eRO System capacity changes significantly with water temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIndicator Lights:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow-Pressure Shutdown\/Auto Restart\u003c\/li\u003e\n\u003cli\u003ePower On\/ Pretreatment Lockout\u003c\/li\u003e\n\u003cli\u003eStorage Tank Full\/System Flush\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications Of The Industrial RO System\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSpot Free Rinse\/Car Wash\/Water Stores\/Whole House\/Hotels Breweries\/Restaurants \/ Laboratories\/Large Office\/Institutions \/ Ice Makers\/Humidification\/Misting \/ Commercial Manufacturing\/Rinse Water \/ And a wide variety of other applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* Minimum recovery rate is calculated based on no concentrate recirculation, it is possible to increase the overall recovery rate by increasing the concentrate circulation flow.\u003cbr\u003e** Permeate flow rate can vary depending on the type of membrane, raw water quality, and recovery rate.\u003c\/p\u003e","brand":"Pure Drop Technicals","offers":[{"title":"Default Title","offer_id":52213833957681,"sku":"RO4000C","price":32000.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0967\/5689\/1953\/files\/4000GPD-RO-System-Chinese-28757487780052.jpg?v=1765987597","url":"https:\/\/plantsprozim.com\/products\/500-litres-per-hour-industrial-ro-system-in-a-cabinet","provider":"Plants Pro","version":"1.0","type":"link"}